Fields of application
OPTI-BASE can also be used for shopfitting and all interior fixtures and fittings, including in kitchens and bathrooms and the fitting out of ship interiors.
Technical specifications
Appearance |
colourless
|
Density series kg/l |
0.924
|
Flow time (+/- 15 %) |
50 s / DIN 53211 - 4 mm
|
Form of delivery |
fluid
|
Non-volatile content series % |
26
|
VOC EU % |
73.779999 %
|
Number of coats (max) |
8
|
Amount per layer (minimum) |
120 g/m²
|
Amount per layer (max) |
200 g/m²
|
Total application volume |
1600 g/m²
|
Mixing ratio (by volume) |
1 : 5 PUR Hardener DR 4034
|
Mixing ratio (gravimetric) |
100 : 551 PUR Hardener DR 4034
|
Ship interior in stained mahogany, high-gloss
Bare wood sanding: 150 - 180 grit (dust removal)
Wiping stain: BE 15-20400
Drying: 2 - 3 h / 20 °C
Isolation: 1 x 120 - 160 g/m² Hesse PUR OPTI-BASE DG 4750, mixing ratio (by volume) 1 : 5 with PU Hardener DR 4034 and addition of 50 % PU Thinner DV 4994 to the lacquer/hardener mixture
Intermediate drying: 20 - 30 min / 20 °C
Isolation: 1 x 120 - 160 g/m² Hesse PUR OPTI-BASE DG 4750, mixing ratio (by volume) 1 : 5 with PU Hardener DR 4034 and addition of 50 % PU Thinner DV 4994 to the lacquer/hardener mixture
Drying: > 16 h / 20 °C
Lacquer sanding: 320 - 400 grit (dust removal)
Basecoat: 1 x 150 - 200 g/m² Hesse PUR OPTI-BASE DG 4750, mixing ratio (by volume) 1 : 5 with PU Hardener DR 4034 and addition of 20 - 25 % PU Thinner DV 4994 to the lacquer/hardener mixture
Intermediate drying: 20 - 30 min / 20 °C
Basecoat: 1 x 150 - 200 g/m² Hesse PUR OPTI-BASE DG 4750, mixing ratio (by volume) 1 : 5 with PU Hardener DR 4034 and addition of 20 - 25 % PU Thinner DV 4994 to the lacquer/hardener mixture
Drying: > 16 h / 20 °C
The more porous the wood, the more basecoats to be applied. Although a maximum application amount in wet film of 400 g/m² may be applied on one working day, since a drying time of > 16 h / 20 °C is then required! Apply sufficient basecoats until the surface to be coated has closed pores prior to lacquer sanding! The drying time for the final basecoat using OPTI-BASE DG 4750 should be > 48 h / 20 °C! PU Thinner DV 4981 can optionally be used at higher temperatures or if very large surfaces are being coated.
Lacquer sanding of the final basecoat: graduating from 400 - 600 grit (dust removal)
Top coat: 1 x 100 - 120 g/m² Hesse PU Brillant lacquer DU 44099, mixing ratio (by volume) 2 : 1 with PU Hardener DR 4080 and addition of 10 - 20 % PU Thinner DV 4994
Intermediate drying: 20 - 30 min / 20 °C
Top coat: 1 x 100 - 120 g/m² Hesse PU Brillant lacquer DU 44099, mixing ratio (by volume) 2 : 1 with PU Hardener DR 4080 and addition of 10 - 20 % PU Thinner DV 4994 to the lacquer/hardener mixture
Packable / ready for polishing: > 3 d / 20 °C
Our technical information is continually adapted to keep up to date with the latest technology and statutory regulations. The latest version is always
available online at www.hesse-lignal.de or talk to your local account manager. This information is for advice and is based on the best knowledge
available and careful research in line with the current state of the art. This information cannot be held as legally binding. We also refer you to our
terms and conditions of business. Safety data sheet is provided in accordance with EC regulation no. 1907/2006.