Fields of application
ADAMANT is perfectly suited for all interior fittings, including those in kitchens, bathrooms and ship interiors, as a top coat on clear Hesse PU base coats or Hesse PU colour lacquers.
Technical specifications
Appearance |
colourless
|
Decopaint basis |
LB
|
Decopaint category |
J
|
Density series kg/l |
0.959
|
Flow time (+/- 15 %) |
40 s / DIN EN ISO 2431 - 3 mm
|
Form of delivery |
fluid
|
Non-volatile content series % |
39
|
Proportion of renewable raw materials % |
19.5
|
VOC EU % |
60.77 %
|
Number of coats (max) |
2
|
Amount per layer (minimum) |
60 g/m²
|
Amount per layer (max) |
250 g/m²
|
Total application volume |
400 g/m²
|
Mixing ratio (by volume) |
1 : 1 PUR Hardener DR 4091
|
Mixing ratio (gravimetric) |
100 : 113 PUR Hardener DR 4091
|
Cabinet fronts in Macassar ebony veneer, high gloss (extremely scratch resistant)
Wood sanding: 150 - 180 grit (dust removal)
Isolation: 1 x 120 - 160 g/m² Hesse PU OPTI-BASE DG 4750, mixing ratio (by volume) 1 : 5 with PU Hardener DR 4034, addition of 50 % PU Thinner DV 4994 to the lacquer/hardener mixture
Intermediate drying: 20 - 30 min / 20 °C
Isolation: 1 x 120 - 160 g/m² Hesse PU OPTI-BASE DG 4750, mixing ratio (by volume) 1 : 5 with PU Hardener DR 4034, addition of 50 % PU Thinner DV 4994 to the lacquer/hardener mixture
Drying: > 16 h / 20 °C
Lacquer sanding: 320 - 400 grit (dust removal)
Basecoat: 1 x 150 - 200 g/m² Hesse PU OPTI-BASE DG 4750, mixing ratio (by volume) 1 : 5 with PU Hardener DR 4034, addition of 20 - 25 % PU Thinner DV 4994 to the lacquer/hardener mixture
Intermediate drying: 20 - 30 min / 20 °C
Basecoat: 1 x 150 - 200 g/m² Hesse PU OPTI-BASE DG 4750, mixing ratio (by volume) 1 : 5 with PU Hardener DR 4034, addition of 20 - 25 % PU Thinner DV 4994 to the lacquer/hardener mixture
Drying: > 16 h / 20 °C
The more porous the wood, the greater the number of basecoats to be applied. Only a maximum of 400 g/m² should be applied in wet film on one working day, then a drying time of > 16 h / 20 °C is required. Apply as many basecoats as are required to ensure the surface is closed-pore prior to lacquer sanding! The final basecoat with OPTI-BASE DG 4750 must be left to dry for > 48 h / 20 °C! PU Thinner DV 4981 can optionally be used at higher temperatures or on very large coating surfaces.
Lacquer sanding of the final basecoat: graduating from 400 - 600 grit (dust removal)
High gloss coat: 1 x 100 - 120 g/m² Hesse ADAMANT DU 48999, mixing ratio (by volume) 1 : 1 with PU Hardener DR 4091, as necessary add 10 - 30 % Thinner CV 553 in relation to the lacquer/hardener mixture
Drying: 20 - 30 min / 20 °C
High gloss coat: 1 x 150 - 250 g/m² Hesse ADAMANT DU 48999, mixing ratio (by volume) 1 : 1 with PU Hardener DR 4091, as necessary add 10 - 30 % Thinner CV 553 in relation to the lacquer/hardener mixture
The finish can be polished to a high gloss as necessary after complete hardening for > 16 h / 20 °C (see separate technical information on our website at www.hesse-lignal.de/Service/ The finish can be polished to a high gloss as necessary after complete hardening for > 16 h / 20 °C (see separate technical information on our website at https://www.hesse-lignal.de/fileadmin/content/documents/Technische_Beschreibungen_deutsch/Schleifen-Polieren_-_3M_Schleif-_und_Polierprozess_ADAMANT_DU_48999_DE.pdf and https://www.hesse-lignal.de/fileadmin/content/documents/Technische_Beschreibungen_deutsch/Schleifen-Polieren_-_Mirka_Polieren_ADAMANT_DU_48999_DE.pdf
Our technical information is continually adapted to keep up to date with the latest technology and statutory regulations. The latest version is always
available online at www.hesse-lignal.de or talk to your local account manager. This information is for advice and is based on the best knowledge
available and careful research in line with the current state of the art. This information cannot be held as legally binding. We also refer you to our
terms and conditions of business. Safety data sheet is provided in accordance with EC regulation no. 1907/2006.