Fields of application
For all interior fittings, including in kitchens and bathrooms. Colouration is possible, for instance with Hesse PU coloured lacquers.
Technical specifications
Appearance |
colourless
|
Density series kg/l |
0.993
|
Flow time (+/- 15 %) |
34 s / DIN 53211 - 4 mm
|
Form of delivery |
fluid
|
Non-volatile content series % |
46
|
VOC EU % |
54.009998 %
|
Number of coats (max) |
1
|
Amount per layer (minimum) |
100 g/m²
|
Amount per layer (max) |
160 g/m²
|
Total application volume |
160 g/m²
|
Mixing ratio (by volume) |
5 : 1 PU Hardener DR 4076-0001
|
Mixing ratio (gravimetric) |
100 : 20 PU Hardener DR 4076-0001
|
Information on use
Usage time |
5 - 6 h / 20 °C
|
Pot life |
8 h / 20 °C
|
Drying |
16 h / 20 °C
|
Stackable after |
> 16 h / 20 °C
|
Complete drying |
7 d / 20 °C
|
Surface preparation |
Substrate preparation is decisive for adhesion of the coating. The glass surface to be coated must be clean and grease-free. Use Hesse Cleaning thinner ZD 101 to carefully clean the surface prior to application.
|
Finishing |
Coating one layer of the same product on top of another is not common and influences the effect and colour.
|
Yield per coat |
6 - 10 m²/l
The spreading rate is heavily dependent on the type of application. The specifications relate to a liter of ready-for-use product, if necessary including hardener and thinner.
|
Storage temperature |
16 - 25 °C
|
Working temperature |
20 °C
|
Processing instructions |
Single-coat application at 130 - 160 g/m² on a carefully-prepared glass substrate is recommended.
|
Particular instructions |
Colouration of 5 - 20 % is possible with Hesse PU Colour lacquers DB 555-(colour tone) or DB 4524x(gloss level)-(colour tone). Harden the entire mixture at mixing ratio (by volume) 5 : 1 with DR 4076-0001. The amount of coating applied when lacquering glass influences the effect and the colour.
|
General instructions on workmanship |
PU Glass colour lacquers should not be applied and dried at material and room temperatures below 18 °C und 40 % RH; ideal values: 20 - 25 °C, 50 - 65 % RH. Deviations result in issues with drying or curing. Old lacquer / hardener mixtures impair the surface quality (bond / resistances). The final hardness of the glass coating will be achieved after one week given proper storage (at least 20 °C room temperature). Conduct a trial coating under practical conditions as necessary!
|
Building construction, glass partition
Substrate preparation: Clean the glass carefully and remove any grease using Hesse glass cleaner ZD 101
Coating: 1 x 130 - 160 g/m² Hesse PU glass lacquer DU 42270-0001 (sandblasted effect), mixing ratio (by volume) 5 : 1 with PU hardener DR 4076-0001, thinned with 10 - 20 % DV 490 or DV 4900
Ready for transport: after drying for at least 16 h / 20 °C
Ready for mounting or glueing: after drying for at least 5 days / 20 °C
Material Safety Data Sheets
Contact
Our technical information is continually adapted to keep up to date with the latest technology and statutory regulations. The latest version is always
available online at www.hesse-lignal.de or talk to your local account manager. This information is for advice and is based on the best knowledge
available and careful research in line with the current state of the art. This information cannot be held as legally binding. We also refer you to our
terms and conditions of business. Safety data sheet is provided in accordance with EC regulation no. 1907/2006.