Fields of application
For high quality glass coating on interior fittings, in shop fitting and in the furniture industry.
Technical specifications
Appearance |
opaque
|
Density series kg/l |
0.942 - 1.155
|
Flow time (+/- 15 %) |
31 s / DIN 53211 - 6 mm
|
Form of delivery |
fluid
|
Non-volatile content series % |
32 - 50
|
VOC EU % |
50.060001 %
|
Number of coats (max) |
2
|
Amount per layer (minimum) |
120 g/m²
|
Amount per layer (max) |
150 g/m²
|
Total application volume |
300 g/m²
|
Mixing ratio (by volume) |
5 : 1 PU Hardener DR 4076-0001
|
Mixing ratio (gravimetric) |
100 : 17 PU Hardener DR 4076-0001
|
Information on use
Usage time |
6 h / 20 °C
|
Pot life |
6 h / 20 °C
|
Drying |
24 h / 20 °C
|
Stackable after |
> 16 h / 20 °C
|
Complete drying |
7 d / 20 °C
|
Surface preparation |
Clean and remove grease from the substrate using Hesse Cleaning agent ZD 101. Careful surface preparation is one of the decisive factors in the adhesion of the coating.
|
Finishing |
After sufficient drying time and intermediate sanding, another coat of the same.
|
Yield per coat |
7 - 9 m²/l
The spreading rate is heavily dependent on the type of application. The specifications relate to a liter of ready-for-use product, if necessary including hardener and thinner.
|
Storage temperature |
16 - 40 °C
|
Working temperature |
20 °C
|
Particular instructions |
When painting on metal, if necessary, perform a test coating!
|
General instructions on workmanship |
PU Glass colour lacquers should not be applied and dried at material and room temperatures below 18 °C und 40 % RH; ideal values: 20 - 25 °C, 50 - 65 % RH. Deviations result in issues with drying or curing. Old lacquer / hardener mixtures impair the surface quality (bond / resistances). The final hardness of the glass coating will be achieved after one week given proper storage (at least 20 °C room temperature). Conduct a trial coating under practical conditions as necessary!
|
Glass partition in sand yellow as per colour tone RAL 1002
Surface preparation: carefully clean and remove grease from the glass using ZD 101
Coating: 1 x 130 - 150 g/m² Hesse PU Glass colour lacquer DB 42395-1002, mixing ratio 5 : 1 (by volume) with PU Hardener DR 4076-0001 and add 20 - 25 % PU Thinner DV 4900 to the lacquer / hardener mixture
Packable: after at least 16 h / 20 °C
Installation or bonding: after 5 d / 20 °C
Material Safety Data Sheets
Contact
Our technical information is continually adapted to keep up to date with the latest technology and statutory regulations. The latest version is always
available online at www.hesse-lignal.de or talk to your local account manager. This information is for advice and is based on the best knowledge
available and careful research in line with the current state of the art. This information cannot be held as legally binding. We also refer you to our
terms and conditions of business. Safety data sheet is provided in accordance with EC regulation no. 1907/2006.