Hesse UV Basecoat for roller UP 7481-(colour tone)

stable colour tones excellent coverage
UV-activated product based on unsaturated acrylate binder, pigmented, high reactivity, good sanding properties, good coverage, ready-to-use with good levelling and optimum colour stability within the overall pigment structure.
Primer for a coloured, closed-pore surface process.
Request product Download data sheet
  • Description
  • Information on use
  • Sample process
  • Safety Data Sheets / Certificates

Fields of application

For residential furniture, doors, etc. on appropriate, freshly cut back UV basecoats.

Technical specifications

Appearance opaque
Density series kg/l 1.639 - 1.836
Flow time 46 s / DIN 53211 - 6 mm
Form of delivery fluid
Non-volatile content series % 100 - 100
VOC EU % 0.01 %
Number of coats (max) 3
Amount per layer (minimum) 10 g/m²
Amount per layer (max) 30 g/m²
Total application volume 60 g/m²

Information on use

Curing A coating structure without lacquer sanding can be achieved using the gelling procedure.
Gelling:
1 Ga and 1 Hg lamp, 80 W/cm, V = 15 - 20 m/min
UV curing:
1 Ga and 1 Hg lamp, 80 W/cm, V = 5 - 7 m/min
Substrate sanding grits from-to 320 - 400
Intermediate sanding (grits) from-to 400 - 600
Comments on sanding The quality and uniformity of the substrate and lacquer sanding are crucial to the final surface quality. After sanding, remove dust as prescribed.
Yield per coat 58 - 174 m²/l

The spreading rate is heavily dependent on the type of application. The specifications relate to a liter of ready-for-use product, if necessary including hardener and thinner.
Storage temperature 5 - 25 °C
conditions of transport frost-free - up to a maximum of 35 °C
Particular instructions It can be recoated using Hesse UV Top coats after gelling or UV activation and fresh sanding.
General instructions on workmanship Clean lamps and reflectors on a regular basis using a soft, lint-free cloth and UV 7111.
Only touch the lamps when wearing cotton gloves. Note the lamp's operating hours and replace them as per the lamp manufacturer's recommendations. Always protect open containers from the incidence of light (cover them).
Seal containers properly after use.
Sufficient lacquer sanding and inspection of the bond within the entire structure will be required in each case. Please apply a trial coating under practical conditions!

The coating process and the precise application parameters should be adapted in each case to the respective application and drying conditions and can be found in the customer-specific process descriptions (surface techniques).

Material Safety Data Sheets

Contact

Our technical information is continually adapted to keep up to date with the latest technology and statutory regulations. The latest version is always available online at www.hesse-lignal.de or talk to your local account manager. This information is for advice and is based on the best knowledge available and careful research in line with the current state of the art. This information cannot be held as legally binding. We also refer you to our terms and conditions of business. Safety data sheet is provided in accordance with EC regulation no. 1907/2006.